At HTR we are convinced that quality of a product can only be assured in its true sense if “QUALITY IS BUILT IN AT SOURCE”. Towards this goal we have established the HTR reliability testing facility, which can carry out the following tests as per JSS / IEC / MIL & JIS specifications and also carry out certain key qualitative tests on essential raw materials.
Electrical tests

DC resistance

Dielectric withstanding voltage

Short time overload

Insulation resistance

Pulse applications

Environmental tests

Load life

Damp heat, steady state

Temperature cycling

Temperature co-efficient

Mechanical tests/Physical tests

Robustness of terminations

Solderability

In Line Testing
100% checking for resistance value with precision digital auto resistance unit.
 
Sample Testing
Selected electrical and environmental tests are performed from samples drawn at random from each batch.
 
Certification
If a customer desires that a certain electrical test should be carried out on a sample basis from his batch, this service and test report to that effect can be provided at an extra chargeable basis.
 
Marking
The standard followed at HTR for marking of resistance value and tolerance is as per DIN / IEC pub 600 62.
For only OA/OP/OF series marking is as per HTR specification.

Support Facilities

To enable HTR reliability testing facility to carry out it’s mandate of checking key raw materials and reliability testing of resistors, the company has installed the following equipment:
  • Precision digital resistance unit.
  • Standard resistors for calibration (0.01% and 0.02% accuracy).
  • High voltage breakdown (flash) tester.
  • Digital insulation tester (Measurement range 1MΩ to 999GΩ).
  • Short time overload tester (up to 10 times rated power for 5 seconds).
  • High voltage / High current pulse tester.
  • Inductance tester.
  • TCR tester – Temperature accuracy ± 1°C Resistance accuracy ± 0.1%.
  • Life tester with programmable power supply console and temperature range of -55°C to +210°C
  • Environment chamber – humidity range 40% to 95% RH ± 3%, temperature range 10°C to 60°C ± 1°C
  • High temperature chamber – upto 250°C with accuracy ± 1°C
  • Robustness of terminations tester.
  • Plating test unit.
  • Pulse tests as per IEC-61000-4-5.
  • Solderability test unit.

(All equipment accuracies are calibrated on standards which are traceable to nationally recognized standards)

 

HTR Resistor Finder Apps For You HTR Resistor Finder - iOS App HTR Resistor Finder - Android App HTR Resistor Finder - Web App
© 2014 Copyright Hi-Tech Resistors Pvt. Ltd.
Digital Marketing By CONVOMAX.